Low emittance 5GeV 6 wigglers in L0. 19kg

July 6, 2007 Lattice: /nfs/cesr/user/dlr/lat/des/CesrTF/ctf_20070705/ctf_20070705_5gev_19kg_6wig

The lattice is designed with 1.9T wiggler field and the parameters indicated in the 1.9T column. If the wiggler field is increased to 2.1T (and no other change to the lattice), the emittance, and the tunes change as indicated. Except for what is shown in this table, all of the calculations referenced on the page are for the design lattice with 1.9T wigglers.
1.9T wigglers 2.1T wigglers
Energy [GeV] 5 5
Qx 14.57 14.569
Qy 9.62 9.628
Qz [9.8MV] 0.05 0.05
Emittance [nm] 3.08 2.89


  • linear lattice constraints
  • non linear lattice constraints energy offset +- 0.0028 and disp

  • lattice file
  • Optical parameters and orbits

  • RF voltage = 9.8MV, Qs=-0.05, Bunch length = 14.3mm


    Tune scan
    Tune scan gif and (initialization) with Qz=-0.05


    Dynamic aperture
    The dynamic aperture gif ( ps ) and (initialization) .Qx=14.57 Qy=9.62,Qz=-0.05. The horizontal and vertical tunes are shifted in order to avoid the synchrobetatron line that shifts with the lower synchrotron tune. (See tune scans)

    Dynamic aperture is computed for fractional energy offset of 0%, 0.5% and 1%. Tracking is based on symplectic integration through the same wiggler map as for CESR-c calculations. Particles are considered lost if their amplitude >> the real physical aperture. (This seems to be the way linear collider damping ring people report dynamic aperture.) The smooth yellow curve corresponds to 3sigma, where sigma is the rms size of the "injected" beam, which is again the custom of damping ring afficiondos. The horizontal emittance of the injected beam is assumed to be 1000nm, and fully coupled so that the vertical emittance is half the horizontal (500nm), just like for the real ILC damping rings. (I believe this is also Jeremy's custom.) And that is real physical emittance, not normalized.


    Analyzer output