Index of /~dlr/g-2/g2/mytest/rfquad/documentation

[ICO]NameLast modifiedSizeDescription

[PARENTDIR]Parent Directory  -  
[   ]Efield_vs_time_vs_quad.gnu2023-12-17 16:04 3.9K 
[   ]Efield_vs_time_vs_quad.pdf2023-12-17 16:06 898K 

January 4, 2024

In rfquad/20240104_170525 - 150k muons, scraping and rf quad
   rfquad/20240105_170554  - RF quad off

January 5, 2024
  Those two above are pretty indistinguishable when plotting moments from Time_Dep_Moments_at_END.dat
  Try flipping sign of horizontal rf amplitude
      20240105_125043
   or doubling the horizontal rf amplitude
      20240105_125341

January 6, 2024
  Unable to distinguish effect of rf in stored distributions from Time_Dep_Moments_at_END.dat
  Check out effect on single particle.

  Set starting point at inflector exit with offset 77mm
    
20240106_085936 - rf on
!<rf_quad(1:4)> freq_h,freq_v,amp_h,amp_v,phi_h,phi_v , t_max, start_h start_v periods_h, periods_v                     
rf_quad(1) = 0.32e6 2.06e6 0.42 -0.2 170. 90. 0 0 3.5e-6 2 6                                                            
rf_quad(2) = 0.32e6 2.06e6 0.42 -0.2 260. 90. 0 0 3.5e-6 2 6                                                            
rf_quad(3) = 0.32e6 2.06e6 0.42 -0.2 170. 90. 0 0 3.5e-6 2 6                                                            
rf_quad(4) = 0.32e6 2.06e6 0.42 -0.2 260. 90. 0 0 3.5e-6 2 6                                                            

20240106_090330 - rf off

January 25, 2024

20240125_12310 out1.dat Having discovered in 20240124_102811 scan starting at rf amplitude of -10 that that
 is the minimium cbo, start another scan from -15. -10.
   Sure enough -10. gives min cbo

Also find minimum in phase scan 20240124_092058 at 153 deg, consider returning there after amp is optimized. 

January 26, 2024
Find a mistake in that phase for q2 is 110 rather than 90 deg from Q1. This in min cbo case.
Set RF as 

rf_quad(1) = 0.32546e6 2.06e6 -10. -0. 153. 90. 0 0 3.5e-6 2 6                                                           
rf_quad(2) = 0.32546e6 2.06e6 -10. -0. 243. 90. 0 0 3.5e-6 2 6                                                           
rf_quad(3) = 0.32546e6 2.06e6 -10. -0. 153. 90. 0 0 3.5e-6 2 6                                                           
rf_quad(4) = 0.32546e6 2.06e6 -10. -0. 240. 90. 0 0 3.5e-6 2 6                                                           

20240126_102233 and scan phase +/- 24,8. Minimum cbo at phi=145.  (see cbo_amp_vs_time_vs_kick.pdf)

January 27, 2024

Try setting q4=q2
! best so far
rf_quad(1) = 0.32546e6 2.06e6 -10. -0. 145. 90. 0 0 3.5e-6 2 6                                                           
rf_quad(2) = 0.32546e6 2.06e6 -10. -0. 235. 90. 0 0 3.5e-6 2 6                                                           
rf_quad(3) = 0.32546e6 2.06e6 -10. -0. 145. 90. 0 0 3.5e-6 2 6                                                           
rf_quad(4) = 0.32546e6 2.06e6 -10. -0. 235. 90. 0 0 3.5e-6 2 6