Introduction

Compare with the regular fit of 3.774 GeV, we use 3.770 GeV.

Process

We fit the psi(3770) with mass 3.770 GeV1. Compare with our regular fits which has mass of 3.774 GeV and width 27.5 GeV. The "diff(%)" is calculated by2:


     /   Yields( test  )         \
    |  --------------------  - 1  |  X 100
     \   Yields(regular)         /

Mode data diff(%)
D0 &rarr K- &pi+ 0.86
D 0&rarr K+ &pi- 0.84
D0 &rarr K- &pi+ &pi0 1.76
D 0&rarr K+ &pi- &pi0 1.82
D0 &rarr K- &pi+ &pi- &pi+ 1.82
D 0&rarr K+ &pi- &pi+ &pi- 1.80
D+ &rarr K- &pi+ &pi+ 1.06
D- &rarr K+ &pi- &pi- 1.08
D+ &rarr K- &pi+ &pi+ &pi0 1.84
D- &rarr K+ &pi- &pi- &pi0 1.84
D+ &rarr KS0 &pi+ 1.38
D- &rarr KS0&pi- 1.26
D+ &rarr KS0 &pi+ &pi0 1.81
D- &rarr KS0&pi- &pi0 1.73
D+ &rarr KS0 &pi+ &pi+ &pi- 2.30
D- &rarr KS0&pi- &pi- &pi+ 2.40
D+ &rarr K+ K- &pi+ 2.16
D- &rarr K- K+ &pi- 2.11

Conclusion

The largest difference is 2.40%.