Earlier

See Tag_Log_Earlier

03/23/2006 -1

Creat the Tag HVTest_DRZD_Fill_B500

Open the current HVNormal settings

$solon5 coundn't connect, get on to the solon4 instead:
$ssh -X solon4
solon4% sethv
solon4% SessionManager

 GUI-> Online -> BDLBrowser :
 BDL Name: HVChannelProperites
 Version Tools -> getTags(unranged): HVNormal_Fill (v 163)

Save the file

~/work/CLEO/service/hv/dat/HVChannelProperties_163_HVNormal_FILL.txt

As:

~/work/CLEO/service/hv/dat/HVChannelProperties_HVTest_DRZD_Fill_B500.txt

Compare with the DROnly_FILL and RUN:

HVChannelProperties_169_HVDROnly_FILL.txt

HVChannelProperties_168_HVDROnly_RUN.txt

Find the where are the DRs:

1 HVPitEast 1469P1 S0S0 0 0 DV 2100
2 HVPitEast 1469P1 S0S0 0 1 DV 2100
3 HVPitEast 1469P1 S0S0 0 2 DV 2100

100 HVPitEast 1469P1 S1S0 2 0 DV 2100
101 HVPitEast 1469P1 S1S0 2 1 DV 2100
102 HVPitEast 1469P1 S1S0 2 2 DV 2100

199 HVPitEast 1469P1 S2S0 4 0 DV 2100
200 HVPitEast 1469P1 S2S0 4 1 DV 2100
201 HVPitEast 1469P1 S2S0 4 2 DV 2100

298 HVPitEast 1469P1 S3S0 6 0 DV 2100
299 HVPitEast 1469P1 S3S0 6 1 DV 2100
300 HVPitEast 1469P1 S3S0 6 2 DV 2100

397 HVPitEast 1469P1 S4S0 8 0 DV 2100
398 HVPitEast 1469P1 S4S0 8 1 DV 2100
399 HVPitEast 1469P1 S4S0 8 2 DV 2100

496 HVPitEast 1469P1 S5S0 10 0 DV 2100
497 HVPitEast 1469P1 S5S0 10 1 DV 2100
498 HVPitEast 1469P1 S5S0 10 2 DV 2100

694 HVPitEast 1469P1 S7S0 14 0 DV 2100
695 HVPitEast 1469P1 S7S0 14 1 DV 2100

991 HVPitWest 1469P1 S0S0 0 0 DV 2100
992 HVPitWest 1469P1 S0S0 0 1 DV 2100
993 HVPitWest 1469P1 S0S0 0 2 DV 2100

1090 HVPitWest 1469P1 S1S0 2 0 DV 2100
1091 HVPitWest 1469P1 S1S0 2 1 DV 2100
1092 HVPitWest 1469P1 S1S0 2 2 DV 2100

1189 HVPitWest 1469P1 S2S0 4 0 DV 2100
1190 HVPitWest 1469P1 S2S0 4 1 DV 2100
1191 HVPitWest 1469P1 S2S0 4 2 DV 2100

1288 HVPitWest 1469P1 S3S0 6 0 DV 2100
1289 HVPitWest 1469P1 S3S0 6 1 DV 2100
1290 HVPitWest 1469P1 S3S0 6 2 DV 2100

1387 HVPitWest 1469P1 S4S0 8 0 DV 2100
1388 HVPitWest 1469P1 S4S0 8 1 DV 2096
1389 HVPitWest 1469P1 S4S0 8 2 DV 2100

1486 HVPitWest 1469P1 S5S0 10 0 DV 2100
1487 HVPitWest 1469P1 S5S0 10 1 DV 2100
1488 HVPitWest 1469P1 S5S0 10 2 DV 2100

1585 HVPitWest 1469P1 S6S0 12 0 DV 2100
1586 HVPitWest 1469P1 S6S0 12 1 DV 2100
1587 HVPitWest 1469P1 S6S0 12 2 DV 2100

1684 HVPitWest 1469P1 S7S0 14 0 DV 2100
1685 HVPitWest 1469P1 S7S0 14 1 DV 2100
1686 HVPitWest 1469P1 S7S0 14 2 DV 2100

Use the DV-500 (i.e. 1000 -> 1600, 1596 for one) as the FILL value, apply that in the HVChannelProperties_HVTest_DRZD_Fill_B500.txt

Find where is the ZD:

Compare

HVChannelProperties_HVNoZD_RUN.txt

HVChannelProperties_174_HVNormal_RUN.txt

892 HVPitEast 1469P1 S9S0 18 0 DV 1900
893 HVPitEast 1469P1 S9S0 18 1 DV 1900
894 HVPitEast 1469P1 S9S0 18 2 DV 1900

2080 HVPitWest 1469P1 S11S0 22 0 DV 1900
2081 HVPitWest 1469P1 S11S0 22 1 DV 1900
2082 HVPitWest 1469P1 S11S0 22 2 DV 1900

Use 1400 as ZD FILL value and change in the HVChannelProperties_HVTest_DRZD_Fill_B500.txt

Upload this to creat the tag:

HVTest_DRZD_Fill_B500 (v 182)

Creat the whole tag

1. HVStateSettings:

GUI-> Online -> BDLBrowser :
      BDL Name : HVStateSettings,
	Version Tools -> getTags(unranged) : HVNormal (1.97)

      RunMinor  : 1.174
      FillMinor : 1.182
      OffMinor  : 1.164

      Write -> Normal
      Tag: HVTest_DRZD_Fill_B500 (1.100)

2. HVBoxConnecton:

Open another BDLBrowser:
      GUI-> Online -> BDLBrowser :
      BDL Name : HVBoxConnection,
	Version Tools -> getTags(unranged) : HVNormal (1.9)
 	Edit-> Edit Values :
  	      Tag: HVTest_DRZD_Fill_B500
	      Creator: xs32
	      Version: 9
        Write -> Normal

3. HVDetectorMap

      GUI-> Online -> BDLBrowser :
      BDL Name : HVDetectorMap,
	Version Tools -> getTags(unranged) : HVNormal (1.16)
 	Edit-> EditValues :
  	      Tag: HVTest_DRZD_Fill_B500
	      Creator: xs32
	      Version: 16
        Write -> Normal

Done

03/23/2006 -2

Creat the Tag HVTest_DRZD_Fill_B300

Save HVChannelProperties_HVTest_DRZD_Fill_B500.txt As: HVChannelProperties_HVTest_DRZD_Fill_B300.txt

(1600 -> 1800 in the txt file) 1388 HVPitWest 1469P1 S4S0 8 1 DV 1596 -> 1796

- Use 1600 as ZD FILL value and change in the HVChannelProperties_HVTest_DRZD_Fill_B300.txt

892 HVPitEast 1469P1 S9S0 18 0 DV 1400 -> 1600
893 HVPitEast 1469P1 S9S0 18 1 DV 1400 -> 1600
894 HVPitEast 1469P1 S9S0 18 2 DV 1400 -> 1600

2080 HVPitWest 1469P1 S11S0 22 0 DV 1400 -> 1600
2081 HVPitWest 1469P1 S11S0 22 1 DV 1400 -> 1600
2082 HVPitWest 1469P1 S11S0 22 2 DV 1400 -> 1600

- Upload this to creat the tag:

HVTest_DRZD_Fill_B300 (v 183)

Creat the whole tag

1. HVStateSettings:

GUI-> Online -> BDLBrowser :
      BDL Name : HVStateSettings,
	Version Tools -> getTags(unranged) : HVNormal (1.97)

      RunMinor  : 1.174
      FillMinor : 1.183
      OffMinor  : 1.164

      Write -> Normal
      Tag: HVTest_DRZD_Fill_B300 (1.101)

2. HVBoxConnecton:

Open another BDLBrowser:
      GUI-> Online -> BDLBrowser :
      BDL Name : HVBoxConnection,
	Version Tools -> getTags(unranged) : HVNormal (1.9)
 	Edit-> Edit Values :
  	      Tag: HVTest_DRZD_Fill_B300
	      Creator: xs32
	      Version: 9
        Write -> Normal

3. HVDetectorMap

      GUI-> Online -> BDLBrowser :
      BDL Name : HVDetectorMap,
	Version Tools -> getTags(unranged) : HVNormal (1.16)
 	Edit-> EditValues :
  	      Tag: HVTest_DRZD_Fill_B300
	      Creator: xs32
	      Version: 16
        Write -> Normal

Done

04/12/2006

1. HVStateSettings:

$ssh -X solon4
solon4% sethv
solon4% SessionManager

 GUI-> Online -> BDLBrowser :
 BDL Name: HVChannelProperites
 Version Tools -> getTags(unranged): HVTest_DRZD_Fill_B500 (v 100)
 	Edit-> Edit Values :
  	      Tag: HVNormal
	      Creator: xs32
	      Version: 100
        Write -> Normal

2. HVBoxConnecton:

Open another BDLBrowser:
      GUI-> Online -> BDLBrowser :
      BDL Name : HVBoxConnection,
	Version Tools -> getTags(unranged) : HVTest_DRZD_Fill_B500 (1.9)
 	Edit-> Edit Values :
  	      Tag: HVNormal
	      Creator: xs32
	      Version: 9
        Write -> Normal

3. HVDetectorMap

      GUI-> Online -> BDLBrowser :
      BDL Name : HVDetectorMap,
	Version Tools -> getTags(unranged) : HVTest_DRZD_Fill_B500 (1.16)
 	Edit-> EditValues :
  	      Tag: HVNormal
	      Creator: xs32
	      Version: 16
        Write -> Normal

Done

04/28/2006

Message from Ji Li:


    In today's HV meeting, we have agreed on using the rich HV box for
    the server debugging, since it has the most modules loaded. For
    this, we need a new set of HV constants which only has the rich
    box in it. The high voltage settings for both Fill and Run
    voltages will be lowered by 500V from the standard settings, i.e.,

    For the anode wires, we will use 500V(Fill), 1000V(Run); and for
    the cathode windows, we will use -300V(Fill), -800V(Run).

    These new Run voltages do not exceed the standard Fill voltages,
    therefore it should be safe for the RICH for these tests.

    Could you please make this set of new constants so we can start
    running the server?

$ssh -X solon4
solon4% sethv
solon4% SessionManager

 GUI-> Online -> BDLBrowser :
 BDL Name: HVChannelProperites
 Version Tools -> getTags(unranged): HVNormal_Fill (v 163)

Save the file

~/work/CLEO/service/hv/dat/HVChannelProperties_163_HVNormal_FILL.txt

As:

~/work/CLEO/service/hv/dat/HVChannelProperties_HVTest_RICHOnly_Fill.txt

Set all the other DV =0 CE=0, except for HVRich:

For the anode wires, we will use 500V(Fill),and for the cathode windows, we will use -300V(Fill)

Save the file Fill as :

~/work/CLEO/service/hv/dat/HVChannelProperties_HVTest_RICHOnly_Run.txt

Replace "DV 500" with "DV 1000" Replace "DV -300" with "DV -800"

1. HVStateSettings:

GUI-> Online -> BDLBrowser :
 BDL Name: HVChannelProperites
 Tools -> Read Constants from File:

~/work/CLEO/service/hv/dat/HVChannelProperties_HVTest_RICHOnly_Fill.txt

      Write -> Normal
      Tag: HVTest_RICHOnly_Fill (1.184)

 Tools -> Read Constants from File:

~/work/CLEO/service/hv/dat/HVChannelProperties_HVTest_RICHOnly_Run.txt

      Write -> Normal
      Tag: HVTest_RICHOnly_Run (1.185)

HVChannelProperites OFF:

.1. HVNormal_OFF: 164 .2. HVMUOnly_OFF: 172 .3. HVNoMU_OFF : 177

Compare them. The same thing actually.

 BDL Name : HVStateSettings,
      Version Tools -> getTags(unranged) : HVNormal (1.100)

      RunMinor  : 1.185
      FillMinor : 1.184
      OffMinor  : 1.177

      Write -> Normal
      Tag: HVTest_RICHOnly (1.103)

2. HVBoxConnecton: (Not sure)

Open another BDLBrowser:
      GUI-> Online -> BDLBrowser :
      BDL Name : HVBoxConnection,
	Version Tools -> getTags(unranged) : HVNormal (1.9)
        Connection type: KEEP The 1 for now.

        Edit-> Edit Values :
  	      Tag: HVTest_DRZD_Fill_B300
	      Creator: xs32
	      Version: 9
        Write -> HVTest_RICHOnly

3. HVDetectorMap (Keep the same)

      GUI-> Online -> BDLBrowser :
      BDL Name : HVDetectorMap,
	Version Tools -> getTags(unranged) : HVNormal (1.16)
 	Edit-> EditValues :
  	      Tag: HVTest_RICHOnly
	      Creator: xs32
	      Version: 16
        Write -> Normal

Ask for more message for the above questions.

05/01/2006

Message from Dan:

Those lines shouldn't be there at all, actually. The same goes for the
DetectorMap. All the lines referring to HVPitEast and West should be
deleted.  You'll have to edit the first line of the text file, in
order for it to list the right number of lines in the file.

2. HVBoxConnection: (Only RICH)

Open another BDLBrowser:
      GUI-> Online -> BDLBrowser :
      BDL Name : HVBoxConnection,
	Version Tools -> getTags(unranged) : HVTest_RICHOnly (1.9)
        Tools -> Write Constants to File:
~/work/CLEO/service/hv/dat/HVBoxConnection_9.txt

        Remove the first two lines. Change the second line number from
        "3" to "1". Save as :
~/work/CLEO/service/hv/dat/HVBoxConnection_HVTest_RICHOnly.txt

Tools -> Read Constants From File:
~/work/CLEO/service/hv/dat/HVBoxConnection_HVTest_RICHOnly.txt

              Write -> Normal :
  	      Tag: HVTest_RICHOnly (1.10)

3. HVDetectorMap (Only RICH)

      GUI-> Online -> BDLBrowser :
      BDL Name : HVDetectorMap,
	Version Tools -> getTags(unranged) : HVNormal (1.16)
        Tools -> Write Constants to File:
~/work/CLEO/service/hv/dat/HVDetectorMap_16_HVNormal.txt

Save as ~/work/CLEO/service/hv/dat/HVDetectorMap_HVTest_RICHOnly.txt

Delete all the HVPitEast and HVPitWest lines. Then count the correct number of lines.

Refere to HVDetectorMap.py

Create HVDetectorMap_RICHOnly.py

./HVDetectorMap_RICHOnly.py -f dat/HVDetectorMap_HVTest_RICHOnly.txt -o dat/HVDetectorMap_HVTest_RICHOnly.txt

Load the new map in the SessionManager:


Tools -> Read Constants From File:
~/work/CLEO/service/hv/dat/HVDetectorMap_HVTest_RICHOnly.txt

              Write -> Normal :
  	      Tag: HVTest_RICHOnly (1.17)
	      Creator: xs32

Done

05/24/2006

Creat Tag : HVTest for all components

Based on HVTest_RICHOnly, the other values are:

Detector FILL RUN
DR 700 1000
ZD 700 1000
MU 1000 1700

HVChannelProperites

HVTest_FILL
Save the current tag:
$ssh -X solon5
solon4% sethv
solon4% SessionManager

 GUI-> Online -> BDLBrowser :
 BDL Name: HVChannelProperites
 Version Tools -> getTags(unranged): HVTest_RICHOnly_Fill (v 184)

Save the file

~/work/CLEO/service/hv/dat/HVChannelProperties_184_HVTest_RICHOnly_FILL.txt

Save as:

~/work/CLEO/service/hv/dat/HVChannelProperties_HVTest_FILL.txt

Change values

1. Set DV = 700, CE=1 for DR

Find the sections for DR:

HVChannelProperties_169_HVDROnly_FILL.txt

Save as HVChannelProperties_HVDROnly_FILL.txt

Change the DV from 1000 to 700

Compare HVDROnly_FILL.txt(a) with HVTest_FILL.txt(b), copy a's region to b's region accordingly.

2. Set DV = 700, CE=1 for ZD

Refere to HVZDOnly_FILL.txt

Set DV 700 in HVTest_FILL.txt:

2080 HVPitWest 1469P1 S11S0 22 0 DV 700
2081 HVPitWest 1469P1 S11S0 22 1 DV 700
2082 HVPitWest 1469P1 S11S0 22 2 DV 700

2092 HVPitWest 1469P1 S11S0 22 0 CE 1
2093 HVPitWest 1469P1 S11S0 22 1 CE 1
2094 HVPitWest 1469P1 S11S0 22 2 CE 1

The other part left untouched

2179 HVPitWest 1469P1 S12S0 24 0 DV 0    -> F1-
2180 HVPitWest 1469P1 S12S0 24 1 DV 200  -> F6+
2181 HVPitWest 1469P1 S12S0 24 2 DV 100  -> F6+

3. Set DV = 1000, CE=1 for MU

Refere to HVMUOnly_FILL.txt

HVChannelProperties_171_HVMUOnly_FILL.txt Save as HVChannelProperties_HVMUOnly_FILL.txt

1882 HVPitWest 1469P1 S9S0 18 0 DV 1000
1883 HVPitWest 1469P1 S9S0 18 1 DV 1000
1884 HVPitWest 1469P1 S9S0 18 2 DV 1000
1894 HVPitWest 1469P1 S9S0 18 0 CE 1
1895 HVPitWest 1469P1 S9S0 18 1 CE 1
1896 HVPitWest 1469P1 S9S0 18 2 CE 1

1981 HVPitWest 1469P1 S10S0 20 0 DV 1000
1993 HVPitWest 1469P1 S10S0 20 0 CE 1
Upload values

HVChannelProperties_HVTest_FILL.txt Tag : HVTest_FILL (187)

HVTest_RUN

Save HVChannelProperties_HVTest_FILL.txt as HVChannelProperties_HVTest_RUN.txt

Change values:

DV 700 -> 1000 MU 1000-> 1700

1882 HVPitWest 1469P1 S9S0 18 0 DV 1700
1883 HVPitWest 1469P1 S9S0 18 1 DV 1700
1884 HVPitWest 1469P1 S9S0 18 2 DV 1700
1981 HVPitWest 1469P1 S10S0 20 0 DV 1700

Upload: Tag : HVTest_RUN (188)

HVStateSettings

 BDL Name : HVStateSettings,
      Version Tools -> getTags(unranged) : HVNormal (1.100)

      RunMinor  : 1.188
      FillMinor : 1.187
      OffMinor  : 1.177

      Write -> Normal
      Tag: HVTest (1.104)

HVBoxConnection

Open another BDLBrowser:
      GUI-> Online -> BDLBrowser :
      BDL Name : HVBoxConnection,
	Version Tools -> getTags(unranged) : HVNormal (1.9)
        Write -> Normal :
        Tag: HVTest (1.11)

HVDetectorMap

      GUI-> Online -> BDLBrowser :
      BDL Name : HVDetectorMap,
	Version Tools -> getTags(unranged) : HVNormal (1.16)
        Edit -> Edit Value
  	Tag: HVTest (1.16)
	Creator: xs32
        Write -> Normal

Done.

05/30/2006

Creat Tag : HVTest_noES6

no HVPitEast S6 in the HVChannelProperties

HVChannelProperties

OFF Version

Open the current version in the SessionManager.

Versioin Number 177, save as HVChannelProperties_177_OFF.txt

Delete the lines with East S6 by hand and save them as HVChannelProperties_177_OFF_del.txt

Then use the script to rearrange the index

HVChannelProperties.py -a 1

The file is saved as HVChannelProperties_HVTest_noES6_OFF.txt

Upload and make the tag name : HVTest_noES6_OFF (v 189)

FILL Version

Save the current : HVChannelProperties_187_HVtest_FILL.txt As : HVChannelProperties_HVtest_FILL_tmp.txt

Delete the lines. Rearrange them

HVChannelProperties.py -a 1
Save as HVChannelProperties_HVTest_noES6_FILL.txt Upload and make the tag name : HVTest_noES6_FILL (v 190)
RUN Version

Save the current : HVChannelProperties_188_HVtest_RUN.txt As : HVChannelProperties_HVtest_RUN_tmp.txt

Delete the lines. Rearrange them

HVChannelProperties.py -a 1
Save as HVChannelProperties_HVTest_noES6_RUN.txt Upload and make the tag name : HVTest_noES6_RUN (v 191)

HVStateSettings

 BDL Name : HVStateSettings,
      Version Tools -> getTags(unranged) : HVTest (1.104)

      RunMinor  : 1.191
      FillMinor : 1.190
      OffMinor  : 1.189

      Write -> Normal
      Tag: HVTest_noES6 (1.105)

HVBoxConnection

Open another BDLBrowser:
      GUI-> Online -> BDLBrowser :
      BDL Name : HVBoxConnection,
	Version Tools -> getTags(unranged) : HVTest (1.11)
        Edit -> Edit Values :
        Tag: HVTest_noES6 (1.11)
        Write -> Normal

HVDetectorMap

      GUI-> Online -> BDLBrowser :
      BDL Name : HVDetectorMap,
	Version Tools -> getTags(unranged) : HVTest (1.16)
        Edit -> Edit Value
  	Tag: HVTest_noES6 (1.16)
	Creator: xs32
        Write -> Normal

Done.

06/12/2006

Revise Tag : HVTest_noES6

shift the LogicalUnit Numbers

HVChannelProperties

OFF Version (v 192)

Open the tag name : HVTest_noES6_OFF (v 189) Save as HVChannelProperties_189_HVTest_noES6_OFF.txt Then save as HVChannelProperties_HVTest_noES6_OFF_tmp.txt

HVPitEast S7S0 14 -> 14-2 = 12 HVPitEast S7S1 15 -> 15-2 = 13

HVPitEast S8S0 16 -> 16-2 = 14 HVPitEast S8S1 17 -> 17-2 = 15

HVPitEast S9S0 18 -> 18-2 = 16 HVPitEast S9S1 19 -> 19-2 = 17

HVChannelProperties.py -a 2

Write out as:

HVChannelProperties_HVTest_noES6_OFF.txt

06/13/2006

Upload and make the tag name : HVTest_noES6_OFF (v 192)

FILL Version (v 193)

Open the tag name : HVTest_noES6_FILL (v 190) Save as HVChannelProperties_190_HVTest_noES6_FILL.txt

HVChannelProperties.py -a 2

Write out as: HVChannelProperties_HVTest_noES6_FILL.txt

Upload and make the tag name : HVTest_noES6_FILL (v 193)

RUN Version (v 195)

Open the tag name : HVTest_noES6_RUN (v 191)

HVChannelProperties.py -a 2

Write out as: HVChannelProperties_HVTest_noES6_RUN.txt

Upload and make the tag name : HVTest_noES6_RUN (v 195)

HVStateSettings

 BDL Name : HVStateSettings,
      Version Tools -> getTags(unranged) : HVTest_noES6 (1.105)

      RunMinor  : 1.195
      FillMinor : 1.193
      OffMinor  : 1.192

      Write -> Normal
      Tag: HVTest_noES6 (1.107)

HVBoxConnection (v 11)

Keeps the same. 1.11

HVDetectorMap (v 19)

Open the tag name : HVTest_noES6 (v 16) Save as HVDetectorMap_16_HVTest_noES6.txt

HVPitEast 14 -> 12 HVPitEast 15 -> 13

HVPitEast 16 -> 14 HVPitEast 17 -> 15

HVPitEast 18 -> 16 HVPitEast 19 -> 17

HVDetectorMap.py -a 1

Write out as: HVDetectorMap_HVTest_noES6.txt

Upload and make the tag name : HVTest_noES6 (v 19)

Done.

Create HVNormal_noES6

No HVPitEast S6 in the HVChannelProperties

HVChannelProperties

OFF Version (v 192)

Just change HVTest_noES6_OFF (v 192) as HVNormal_noES6_OFF (v 192)

FILL Version (v 199)

Open the tag name : HVNormal_FILL (v 163) Save As : HVChannelProperties_163_HVNormal_FILL.txt Delete the lines with HVPitEast S6 .

HVChannelProperties.py -a 1
Write out as : HVChannelProperties_HVNormal_noES6_FILL.txt

Change the LogicalUnitNumber:

HVChannelProperties.py -a 2

Upload and make the tag name : HVNormal_noES6_FILL (v 199)

RUN Version (v 200)

Open the tag name : HVNormal_RUN (v 174) Save As : HVChannelProperties_174_HVNormal_RUN.txt Delete the lines with HVPitEast S6 .

HVChannelProperties.py -a 1

Write out as : HVChannelProperties_HVNormal_noES6_RUN.txt Change the LogicalUnitNumber:

HVChannelProperties.py -a 2

Upload and make the tag name : HVNormal_noES6_RUN (v 200)

HVStateSettings (v 109)

 BDL Name : HVStateSettings,
      Version Tools -> getTags(unranged) : HVTest_noES6 (1.107)

      RunMinor  : 1.200
      FillMinor : 1.199
      OffMinor  : 1.192

      Write -> Normal
      Tag: HVNormal_noES6 (1.109)

HVBoxConnection (v 9)

Keeps the same. 1.9

HVDetectorMap (v 19)

Open the tag name : HVTest_noES6 (v 16) Edit as HVNormal_noES6 (v 19)

Done.

06/16/2006

Create Tag : HVNormal_noES6_noRICH

HVChannelProperties

OFF Version (v 192)

Use the same as the HVNormal_noES6, create Tag: HVNormal_noES6_noRICH (v 192)

FILL Version (v 201)

Open the HVNormal_noES6_FILL, (v 199) Save as: ~/work/CLEO/service/hv/dat/HVChannelProperties_199_HVNormal_noES6_FILL.txt

Save as: HVChannelProperties_HVNormal_noES6_noRICH_FILL.txt Set the DV and CE in RICH = 0 HVChannelProperties.py -a 3

Write to: HVChannelProperties_HVNormal_noES6_noRICH_FILL_tmp.txt

Upload and make tag: HVNormal_noES6_noRICH_FILL (v 201)

RUN Version (v 202)

Open the HVNormal_noES6_RUN, (v 200) Save as: ~/work/CLEO/service/hv/dat/HVChannelProperties_200_HVNormal_noES6_RUN.txt

Set the DV and CE in RICH = 0 and Save as: HVChannelProperties_HVNormal_noES6_noRICH_RUN.txt

HVChannelProperties.py -a 3

Upload and make tag: HVNormal_noES6_noRICH_RUN (v 202)

HVStateSettings

 BDL Name : HVStateSettings,
      Version Tools -> getTags(unranged) : HVNormal_noES6 (1.109)

      RunMinor  : 1.202
      FillMinor : 1.201
      OffMinor  : 1.192

      Write -> Normal
      Tag: HVNormal_noES6_noRICH (1.110)

HVBoxConnection: (No RICH)

Open another BDLBrowser:
      GUI-> Online -> BDLBrowser :
      BDL Name : HVBoxConnection,
	Version Tools -> getTags(unranged) : HVNormal_noES6 (1.9)
        Tools -> Write Constants to File:
~/work/CLEO/service/hv/dat/HVBoxConnection_9.txt

        Remove the last line of RICH. Change the second line number from
        "3" to "2". Save as :
~/work/CLEO/service/hv/dat/HVBoxConnection_HVNormal_noRICH.txt

Tools -> Read Constants From File:
~/work/CLEO/service/hv/dat/HVBoxConnection_HVNormal_noRICH.txt

              Write -> Normal :
  	      Tag: HVNormal_noRICH (1.12)

Link to another tag name: HVNormal_noES6_noRICH (1.12)

HVDetectorMap (No RICH)

      GUI-> Online -> BDLBrowser :
      BDL Name : HVDetectorMap,
	Version Tools -> getTags(unranged) : HVNormal_noES6 (1.19)
        Tools -> Write Constants to File:
~/work/CLEO/service/hv/dat/HVDetectorMap_19_HVNormal_noES6.txt

Delete all the HVRich lines and count the correct number of lines. Then save as ~/work/CLEO/service/hv/dat/HVDetectorMap_HVNormal_noES6_noRICH.txt by using HVDetectorMap.py.

06/19/2006

HVDetectorMap.py -a 2

Write to: ~/work/CLEO/service/hv/dat/HVDetectorMap_HVNormal_noES6_noRICH.txt

Load constants, Tag: HVNormal_noES6_noRICH (v 20)

Done.

06/30/2006

Message from Hubert

E-log

The following channels have zero DV in the HVNormal_noES6_FILL HVChannelProperties constants:

696 HVPitEast 1469P1 S8S0 14 2 DV 0
793 HVPitEast 1469P1 S9S0 16 0 DV 0
794 HVPitEast 1469P1 S9S0 16 1 DV 0
795 HVPitEast 1469P1 S9S0 16 2 DV 0
1883 HVPitWest 1469P1 S10S0 20 1 DV 0
2080 HVPitWest 1469P1 S12S0 24 0 DV 0
3070 HVRich 1469N1 S9S0 18 0 DV 0

Check the RUN first

HVNormal_noES6_RUN

HVChannelProperties_200_HVNormal_noES6_RUN.txt

696 HVPitEast 1469P1 S8S0 14 2 DV 0  ... OK.
793 HVPitEast 1469P1 S9S0 16 0 DV 0  <= 700
794 HVPitEast 1469P1 S9S0 16 1 DV 0  <= 700
795 HVPitEast 1469P1 S9S0 16 2 DV 0  <= 700

1883 HVPitWest 1469P1 S10S0 20 1 DV 0 ... OK
2080 HVPitWest 1469P1 S12S0 24 0 DV 0 ... OK
3070 HVRich 1469N1 S9S0 18 0 DV 0     ... OK

Change directly on the SessionManager

So, change the lines in the HVNormal_noES6_FILL

793 HVPitEast 1469P1 S9S0 16 0 DV 0  => 700
794 HVPitEast 1469P1 S9S0 16 1 DV 0  => 700
795 HVPitEast 1469P1 S9S0 16 2 DV 0  => 700

Write HVNormal_noES6_FILL (v 203)

Change the StateSettings

Fill to 203

Save HVNormal_noES6 (v 111)

OK.

Find out where the error happend

Reproduce the original one

Input file: HVChannelProperties_163_HVNormal_FILL.txt Delete the lines with HVPitEast S6 .

HVChannelProperties.py -a 1
Write out as : HVChannelProperties_HVNormal_noES6_FILL_1.txt

Change the LogicalUnitNumber:

HVChannelProperties.py -a 2

Compare the HVChannelProperties_HVNormal_noES6_FILL_1.txt with: HVChannelProperties_HVNormal_noES6_FILL.txt

Get the current 203 version of FILL

HVChannelProperties_203_HVNormal_noES6_FILL.txt

07/01/2006

Message from Dan

The standard DV for fill/RUN is:
DR:1000 / 2100
ZD: 900 / 1900
MU: 1700 / 2400
RICH Anode: 1000 / ~1500
RICH Cathode: 800 / ~1200

The DRCA is at 370 for both. The F1- for the DR is 200, as is F6+ for
the ZD. The F1- of the ZD is at 100.

Clarify the HVNormal_noES6 Tag

Start from the HVNormal Tag

FILL Version 163 RUN Version 174

Input file: HVChannelProperties_163_HVNormal_FILL.txt Input file: HVChannelProperties_174_HVNormal_RUN.txt

Save the last edited file:

HVChannelProperties_HVNormal_noES6_FILL.bak HVChannelProperties_HVNormal_noES6_RUN.bak

HVChannelProperties.py -a 1

HVChannelProperties_HVNormal_noES6_FILL.txt HVChannelProperties_HVNormal_noES6_RUN.txt -> is the same as before.

Upload FILL (v 204)

StateSettings

Fill to 204

Save HVNormal_noES6 (v 112)

Done.

07/25/2006

# 07/25/2006

Rename the HVNormal_noES6 to HVNormal

HVDetectorMap

      GUI-> Online -> BDLBrowser :
      BDL Name : HVDetectorMap,
	Version Tools -> getTags(unranged) : HVNormal_noES6 (1.21)
      Edit -> Edit Values: HVNormal
      Write -> Normal

HVChannelProperties

      Version Tools -> getTags(unranged) : HVNormal_noES6_OFF (1.192)
      Edit -> Edit Values: HVNormal_OFF
      Write -> Normal

      Version Tools -> getTags(unranged) : HVNormal_noES6_FILL (1.204)
      Edit -> Edit Values: HVNormal_FILL
      Write -> Normal

      Version Tools -> getTags(unranged) : HVNormal_noES6_RUN (1.200)
      Edit -> Edit Values: HVNormal_RUN
      Write -> Normal

HVStateSettings

      Version Tools -> getTags(unranged) : HVNormal_noES6 (1.112)
      Edit -> Edit Values: HVNormal
      Write -> Normal

HVBoxConnection (1.9 Keep the same)

Done.