10/16/2007

DR Layer 35, Sector 7-9

Test the current in the HVPitWest, S6S1.10.

Voltage (V) Current (uA)
500 1.00
1000 2.00
2000 4.02
2100 4.22

No high current observed. So, we need to review the previous record before doing the further jumpering work.

Put on e-log. Done.

11/02/2007

Test HV boards 1, 2, 16, 46

All labeled "Repaired 10/26/07"

Passed 2100V for 5 minutes for all 3 bulks.

Passed 2100V for 10 minutes for all 3 bulks.

Passed 2100V for 10 minutes for all 3 bulks.

Passed 2100V for 10 minutes for all 3 bulks.

Update the ModuleLog file:

Module Log

Update the spareboard info page:

Spare Boards

Post on e-log.

11/06/2007

Replace #38 with #16

The HV#38's problem:

Bulk 0 trips at 1800V after 20 secondes.

Update the Module Log

Spare Boards

Write to E-log.

11/22/2007

Update Detector Map

Get the latest DetectorMap from GUI.

Save as:

/home/xs32/work/CLEO/service/hv/dat/solon/
HVChannelProperties_HVNormal_RUN_235.txt  HVDetectorMap_HVNormal_27.txt

Update the page:

https://www.lns.cornell.edu/restricted/CLEO/RunMgmt/detectors/hv/HVDetectorMap.html

Need the Slot and Subslot info from the HVChannelProperties file.

cd /home/xs32/work/CLEO/service/hv/dat/solon/
hv update html HVDetectorMap HVChannelProperties_HVNormal_RUN_235.txt  HVDetectorMap_HVNormal_27.txt

output the HVDetectorMap.tab

Next to translate to html.

11/25/2007

Translate the table into html

cd /home/xs32/work/CLEO/service/hv/dat/solon/
hv update html HVDetectorMap

Output html:

HVDetectorMap.html

11/26/2007

Update the constants HVNoZD

solon2:

hv update tag HVNoZD

Please update in SessionManager:
    BDL Name: HVDetectorMap
    Tag Name: HVNoZD
    Version : 23 => 27
xs32_solon2% hv update tag HVNoZD
--------------------------------------
     CLEO-c High Voltage System
--------------------------------------

 Update Tag :

             HVNoZD
up-to-date: HVDetectorMap,HVNoZD
xs32_solon2%

/nfs/online/cleo31/run/tools/HVConstantsWrite

Next:

ChannelProperties update

11/27/2007

Update the constants HVNoZD cont.

solon2:
hv update tag HVNoZD --upload

--------------------------------------
     CLEO-c High Voltage System
--------------------------------------

 Update Tag :

             HVNoZD

up-to-date: HVDetectorMap,HVNoZD
Uploading ... /home/xs32/work/CLEO/service/hv/dat/HVChannelProperties_209_New_HVNoZD_OFF.asc
HVChannelProperties,HVNoZD_OFF version upgraded to 238.
Uploading ... /home/xs32/work/CLEO/service/hv/dat/HVChannelProperties_210_New_HVNoZD_FILL.asc
HVChannelProperties,HVNoZD_FILL version upgraded to 239.
Uploading ... /home/xs32/work/CLEO/service/hv/dat/HVChannelProperties_211_New_HVNoZD_RUN.asc
HVChannelProperties,HVNoZD_RUN version upgraded to 240.
Uploading ... /home/xs32/work/CLEO/service/hv/dat/HVStateSettings_115_New_HVNoZD.asc
HVStateSettings,HVNoZD version upgraded to 128.
up-to-date: HVBoxConnection,HVNoZD
Done.

Need to check the map GUI.

11/28/2007

Update the constants HVNoZD cont - Check the map GUI

OK.

Write message on the E-log.


There seems to be mis-match.

Muon sections are off.

Let me try that again, some DR Cathode octants are off/disabled.

solon2:
hv update tag HVNoZD

hv get version HVChannelProperties HVNormal_RUN

12/03/2007

Fix the HVNoZD_OFF problem

Message from Ji Li:

 You've made some mistakes in HVNoZD_OFF. Some of the DRCA channels in
 logic unit-15(PitEast, slot-8) are disabled. I did not change
 them.

Get the lates file:

solon2:

hv get const HVChannelProperties HVNoZD_OFF


up-to-date: /home/xs32/work/CLEO/service/hv/dat/HVChannelProperties_238_HVNoZD_OFF.asc

hv get const HVChannelProperties HVNormal_OFF

up-to-date: /home/xs32/work/CLEO/service/hv/dat/HVChannelProperties_237_HVNormal_OFF.asc

HVStateSettings for HVNormal is using the 227,228,229, however, the latest HVNormal(OFF) is 237.

Compare the HVNormal(OFF) 237 with 227:

hv get const HVChannelProperties 227

up-to-date: /home/xs32/work/CLEO/service/hv/dat/HVChannelProperties_227.asc

hv get const HVChannelProperties 237

up-to-date: /home/xs32/work/CLEO/service/hv/dat/HVChannelProperties_237.asc

The difference in these two files:

666 HVPitEast 1469P1 S7S1 13 20 CE 1 -> 0   (227-> 237)
668 HVPitEast 1469P1 S7S1 13 22 CE 1 -> 0

Found the reason on log page:

https://www.lepp.cornell.edu/~xs32/private/hv/archives/2007/07.html#sec14

which also has the link to the original E-log.

So, update the HVNormal to the latest version just for simplicity.

hv upload HVChannelProperties /home/xs32/work/CLEO/service/hv/dat/HVChannelProperties_227.asc xs32 HVNormal_OFF

Uploading ... /home/xs32/work/CLEO/service/hv/dat/HVChannelProperties_227.asc
HVChannelProperties,HVNormal_OFF version upgraded to 241.


hv get const HVChannelProperties 228
hv upload HVChannelProperties /home/xs32/work/CLEO/service/hv/dat/HVChannelProperties_228.asc xs32 HVNormal_FILL

HVChannelProperties,HVNormal_FILL version upgraded to 242.


hv get const HVChannelProperties 229
hv upload HVChannelProperties /home/xs32/work/CLEO/service/hv/dat/HVChannelProperties_229.asc  xs32 HVNormal_RUN

HVChannelProperties,HVNormal_RUN version upgraded to 243.

Then, do a HVStateSettings update for the HVNormal

hv update HVStateSettings HVNormal --upload

HVStateSettings,HVNormal version upgraded to 129.

Now, do the update for the HVNoZD:

hv update tag HVNoZD --upload

Test the HVNormal. Reset the HVBox by pushing the red buttons for 3 seconds. OK now.

Write to E-log.

Next: Inverse DetectorMap

12/05/2007

Inverse DetectorMap

Original map page:

https://www.lns.cornell.edu/restricted/CLEO/RunMgmt/detectors/hv/HVInverseMap.html

cd /home/xs32/work/CLEO/service/hv/dat/solon/


hv update html HVInverseMap test.tab